On Thu, Jun 08, 2017 at 11:52:45AM +0200, Heiko Schocher wrote:
fit_image_verify_required_sigs() must return != 0, on error.
When fit_image_verify_required_sigs() does not find a signature node, it returns 0, which leads in booting a signed FIT image.
Fix this!
Signed-off-by: Heiko Schocher hs@denx.de
Good catch. Did you confirm that the sandbox tests still work? And can you construct a new test for this case? Thanks!
--