RNG Hardware error is reported due to incorrect entropy delay rng self test are run to determine the correct ent_dly. test is executed with different voltage and temperature to identify the worst case value for ent_dly. after adding a margin value(1000), ent_dly should be at least 12000. Signed-off-by: Gaurav Jain gaurav.jain@nxp.com Reviewed-by: Fabio Estevam festevam@denx.de
Applied to u-boot-imx, master, thanks !
Best regards, Stefano Babic
--
=====================================================================
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: sbabic@denx.de
=====================================================================