On Mon, Jan 7, 2013 at 1:23 AM, Lukasz Majewski l.majewski@samsung.com wrote:
lcd_set_flush_dcache(1) function is called from trats configuration file to enable lcd_sync function.
Tested-at: TRATS (Exynos 4210) Tested-by: Lukasz Majewski l.majewski@samsung.com Signed-off-by: Lukasz Majewski l.majewski@samsung.com Signed-off-by: Kyungmin Park kyungmin.park@samsung.com Cc: Minkyu Kang mk7.kang@samsung.com
Acked-by: Simon Glass sjg@chromium.org
board/samsung/trats/trats.c | 3 +++ 1 files changed, 3 insertions(+), 0 deletions(-)
diff --git a/board/samsung/trats/trats.c b/board/samsung/trats/trats.c index 88d193d..5d0fdd0 100644 --- a/board/samsung/trats/trats.c +++ b/board/samsung/trats/trats.c @@ -789,5 +789,8 @@ void init_panel_info(vidinfo_t *vid) s6e8ax0_init(); exynos_set_dsim_platform_data(&s6e8ax0_platform_data);
/* Enable flushing after LCD writes if requested */
lcd_set_flush_dcache(1);
setenv("lcdinfo", "lcd=s6e8ax0");
}