On Tue, Apr 11, 2017 at 01:37:21PM -0500, Franklin S Cooper Jr wrote:
In non DM I2C read operations the address length passed in during a read operation will be used automatically. However, in DM I2C the address length is set to a default value of one which causes problems when trying to perform a read with a differing alen. Therefore, before the first read in a series of read operations set the alen to the correct value.
Signed-off-by: Franklin S Cooper Jr fcooper@ti.com
Reviewed-by: Tom Rini trini@konsulko.com
--