Hello Simon,
Am 11.11.2014 18:46, schrieb Simon Glass:
The concept of a 'current bus' is now implemented in the command line rather than in the uclass. Also the address length does not need to be specified with each command - really we should consider dropping this from most commands but it works OK for now.
Signed-off-by: Simon Glass sjg@chromium.org
Changes in v2:
Change alen to int so that it can be -1 (this was a bug)
Call the deblock() method for 'i2c reset'
common/cmd_i2c.c | 336 ++++++++++++++++++++++++++++++++++++++++++++++--------- 1 file changed, 284 insertions(+), 52 deletions(-)
Acked-by: Heiko Schocher hs@denx.de
bye, Heiko
--