On Wed, Oct 13, 2021 at 10:40 AM Lukasz Majewski lukma@denx.de wrote:
The imx28 uses following voltage supplies hierarchy:
VDD_5V (VDD_BAT) -> VDDIO -> VDDA -> VDDMEM -----> VDDD
One shall first enable DCDC on the parent source (VDDIO) and then follow with its children.
Signed-off-by: Lukasz Majewski lukma@denx.de
Reviewed-by: Fabio Estevam festevam@gmail.com