On Thu, Jan 9, 2020 at 2:50 AM Alex Marginean alexandru.marginean@nxp.com wrote:
The helper is used to reset PHYs on connect and it determines the clause to use (C22/C45) based on interface type. This fixes 'PHY reset timed out' warnings in console for USXGMII/XFI PHYs.
Signed-off-by: Alex Marginean alexandru.marginean@nxp.com
Acked-by: Joe Hershberger joe.hershberger@ni.com